| Property | Value |
|---|---|
| PTX# | 21052 |
| Price | $59,500 |
| kW Rating | 400 |
| Hours | 43 |
| Condition | Used |
| Engine Manufacturer | Cummins |
| Engine Model | QSX15-G9 |
| Engine S/N | 14026700 |
| Engine HP | 563 |
| Engine RPM | 1800 |
| Governor | Electronic |
| Starter | Electric |
| Cooling Method | Radiator |
| Emissions Rating | Tier 2 |
| Generator End Manufacturer | Newage |
| Generator End Model | GGHE-6009641 |
| Generator End S/N | A080145104 |
| kVA Rating | 500 |
| Rating Type | Standby |
| Voltage | 480/277 |
| Power Factor | 0.8 |
| Frequency | 60Hz |
| Phase | 3 Phase |
| Leads | 12 |
| Bearings | Single |
With just 43 recorded operating hours, this used Cummins QSX15-G9 generator set is worth considering for buyers looking for a high-capacity standby power solution. The unit delivers 400kW of standby power and has a 500kVA rating, making it suitable for evaluation across commercial and industrial applications.
Its Cummins QSX15-G9 engine produces 563 HP and operates at 1,800 RPM. The engine features an electronic governor, electric starting system, and radiator cooling. The generator end is manufactured by Newage and uses a 12-lead configuration. The electrical specifications include 480/277V output, three-phase power, 60Hz frequency, and a 0.8 power factor. Listed with an EPA Tier 2 emissions rating, this generator gives buyers several important technical details to consider when planning a backup power installation.
A 400kW standby generator can be relevant to facilities where a power interruption would affect important equipment, services, or business operations.
The 400kW standby rating should be compared with your facility’s actual electrical demand. Consider running loads, motor-starting requirements, peak demand, and the equipment that must remain operational during an outage. The 500kVA rating and 0.8 power factor are also important when planning the electrical system.
The 480/277V output, three-phase configuration, and 60Hz frequency must match the site’s distribution equipment. Have a qualified electrician check the Newage generator end, 12-lead connections, transfer switch, grounding, and protection systems.
The 43 recorded hours provide a useful starting point, but they do not tell the complete condition of a used generator. Request available maintenance records, inspection results, and load-bank test documentation. Buyers should also verify the Tier 2 emissions documentation against the requirements that apply at the intended installation location.
Power Trade X helps customers evaluate generator equipment according to their required capacity, electrical setup, and intended application. For this Cummins QSX15-G9, the main considerations include its 400kW standby rating, Newage generator end, 480/277V output, and Tier 2 emissions classification.
Once the equipment has been reviewed for suitability, our team can assist with purchase coordination and nationwide transportation. We recommend involving qualified electrical and mechanical professionals before delivery to prepare the installation site and confirm connection requirements.
Every unit sold through Power Trade X is load-bank tested and inspection-verified before it ships. We document the results and provide them to the buyer. We coordinate transportation and logistics nationwide, from single-unit deliveries to multi-unit fleet placements. Our team has 35+ years of combined industry experience sourcing, inspecting, and selling generators and air compressors across the United States.
Questions about this unit? Call 888-769-3780 or submit your inquiry online for same-business-day service.
The unit is rated at 400kW standby and 500kVA. Buyers should compare these ratings with their facility’s calculated demand and backup power requirements.
This used generator has 43 recorded hours. Review its maintenance history, inspection findings, and test documentation alongside the operating-hour figure.
It uses a Cummins QSX15-G9 engine rated at 563 HP and operating at 1,800 RPM. The engine also features an electronic governor and electric starting system.
The generator end is manufactured by Newage and has a 12-lead configuration. Buyers should have a technician verify its connections and electrical compatibility before installation.
The listed output is 480/277V at 60Hz with three-phase power. These specifications should match the facility’s electrical distribution and connected equipment.
Tier 2 identifies the engine’s listed emissions classification. Buyers should verify the applicable emissions documentation and confirm local requirements before purchasing.
An electronic governor controls engine speed to help maintain the required operating frequency as electrical demand changes. Proper operation should be confirmed during inspection and testing.
The radiator cooling system helps regulate engine temperature during operation. Buyers should review the cooling system’s condition and maintenance history before putting the generator into service.
The supplied specifications identify 400kW as the standby rating. Confirm the applicable prime or continuous rating before considering extended operation.
Review inspection reports, load-bank test results, maintenance records, and emissions documents. Also confirm the voltage, phase, frequency, and generator capacity match your installation requirements.
No documents are currently published for this unit. Contact PTX to request available specifications or test reports.